During the arrangement of the wire,The interval between strong and weak electricity should be greater than 15cm

Source:www.xysd023.com & nbsp & nbsp & nbsp & nbsp Release time: 2023-10-28
& emsp; & emsp; Hydropower in the decoration belongs to the hidden project。If the quality is not qualified,It will bring a lot of trouble to our future life。The master of the decoration tells me,The details below must pay close attention。
& emsp; & emsp; decorate hydropower and pay attention to 10 points:
& emsp; & emsp; 1. The distance between the hot and cold water pipe should be greater than 15 cm。
& emsp; & emsp; 2. The water road is below,The circuit is above,Avoid the circuit when avoiding water pipes。
& emsp; & emsp; 3. After laying the water pipe,Pressure test should be performed,Check whether the performance of the water pipe seal is tight。
& emsp; & emsp; 4. Install the S -type anti -odor curve under the basin,Prevent odor to float。
& emsp; & emsp; 5. After paving the kitchen and bathroom floor tiles,Should be stored in water,See if the drainage of the floor drain is smooth。
& emsp; & emsp; 6. The lighting line adopts 1.5 square line,The socket uses 2.5 square line,Big power appliances use 4 square lines,Such as a kitchen、bathroom、Each air conditioner should walk separately。
& emsp; & emsp; 7. The air switch is not bigger and better,The limit is unable to work,Small quota is easy to stick to。
& emsp; & emsp; 8. One line tube penetration is controlled within three,Preventing the poor heat dissipation of the wires and causing hidden dangers。
& emsp; & emsp; 9. Wall hanging TV,Hurrying a 50pvc line tube after the background wall,can hide network cables and wires。
& emsp; & emsp; 10. The water circuit transformation should leave drawings,Take pictures,indicate size,Installation of the wall on the wall,Avoid damage to the water circuit pipeline。
& emsp; & emsp; bomb lines are divided into horizontal lines and pipes。The purpose of the horizontal line is to make all switches and sockets,Installed on the same horizontal line,Convenient wiring,More beautiful; the direction line is to make the line horizontally vertically,More neat,Easy to maintain and check in the future,Avoid postponing damage lines in the later period。
& emsp; & emsp; slot along the bomb line,General machine,can better guarantee the level of the wire slot、Vertical、Smooth,slot depth is not less than 25mm。
& emsp; & emsp; after slotting,embedding the bottom box,The horizontal deviation between the bottom box does not exceed 5mm。After the bottom box is buried,Fix the gap around the surrounding,Fixed bottom box,Clean up the internal box。
& emsp; & emsp; fixed buckle,After fixing the electric pipe,Make it not suitable for falling off。
& emsp; & emsp;,Line management requires horizontal vertical arrangement,Aesthetic,It is convenient to find the position according to the circuit direction diagram,Convenient for maintenance in the future,Avoid accidentally damaging the pipeline in the future。During the arrangement of the wire,The interval between strong and weak electricity should be greater than 15cm,To avoid magnetic field interference。Pipeline bending angle、Special processing process at the intersection of strong and weak electricity,Special crafts on the wiring head。